Product Details:

Place of Origin: China
Brand Name: SRI
Certification: ISO 9001:2000
Model Number: MJ-EC-CHN

Payment & Shipping Terms:

Minimum Order Quantity: 1set
Price: 5000-15000USD/set
Packaging Details: Standard exporting package
Delivery Time: 10-15 working days
Payment Terms: T/T, L/C, PAYPAL
Supply Ability: 50 sets/month
Minimum Order Quantity: 1set
Contact Now
Detailed Product Description
Function: Carbon Hydrogen And Nitrogen Content Test Category: Coal Coke Analysis Instrument
Sample Feed: Automatic/manual Sample Drying: Nitrogen Drying Method Or Air Drying Method

It is applicable to determine the content of carbon, hydrogen and nitrogen in solid materials such as coal and coke.

 

Features

◎ 39 samples can be set out at one time, and 78 samples can be purchased at one time. The instrument can automatically send samples, set samples, and conduct cyclic testing. The whole process does not require manual operation after setting out, and samples can be added, subtracted, and replaced at any time during the analysis process;

◎ The horizontal structure is adopted, and the instrument can be placed on the laboratory table, which is convenient for customers to operate;

◎ The advanced PID algorithm is used to control the temperature, the furnace temperature control accuracy can reach ± 1 ℃, and the temperature control accuracy of the thermostatic chamber and the air tank can reach ± 0.1 ℃;

◎ The absolute pressure sensor is used to monitor the pressure of the whole gas path of the instrument, which can automatically detect the air tightness of the whole gas path and the furnace, infrared pool, thermal conductivity pool, and gas storage tank;

◎ The instrument adopts infrared spectrum absorption method to determine carbon content and hydrogen content, and thermal conductivity method to determine nitrogen content;

◎ Fast test speed, high degree of automation, and the time for testing carbon, hydrogen and nitrogen is about 4 minutes;

◎ During the experiment, the option of "automatic cooling after the experiment" can be selected. After the experiment is completed, the computer will automatically shut down and the instrument will automatically cool down. No one can be on duty. No personnel are required to manually cool down and shut down after the test is completed;

◎ The experimental report can be prepared according to the customer's requirements to reduce the customer's workload;

◎ It can be connected to the laboratory management system to ensure that the balance data does not fall to the ground, and the test results are backed up and uploaded.

 

Specifications

Model MJ-EC-CHN MJ-EC-CH MJ-EC-H MJ-EC-HM
Measure range C:0.005%~100%,H:0.01%~60%,N:0.008%~60% C:0.005%~100%, H: 0.01%~60% H:0.01%~60% H:0.01%~20%
Method Infrared spectral absorption thermal conductivity method Infrared spectral absorption Infrared spectral absorption Coulomb method
Repeatability C(Cad≤0.5%),H(Had≤0.15%),N(Nad≤0.08%) C(Cad≤0.5%),H(Had≤0.15%) H(Had≤0.15%) H(Had≤0.15%)
Accuracy Within the uncertainty range of the standard sample Within the uncertainty range of the standard sample Within the uncertainty range of the standard sample Within the uncertainty range of the standard sample
Temp. range RT+10~1050℃, ±1℃ RT+10~1050℃, ±1℃ RT+10~1050℃, ±1℃ RT+10~850℃, ±1℃
Sample quantity Recommend 80~100mg Recommend 80~100mg Recommend 80~100mg 70±5mg
Sample feeding Automatic Automatic Automatic Manual
Sample quanatity 39 Pieces/batch, add/replace samples during the test, and purchase 78 sample trays for one-time setting out 39 Pieces/batch, add/replace samples during the test, and purchase 78 sample trays for one-time setting out 39 Pieces/batch, add/replace samples during the test, and purchase 78 sample trays for one-time setting out 1
Single sample process time 4min 4min 4min 8-15mins
Carrier gas Helium, purity ≥ 99.995%, pressure 0.25 ± 0.1MPa Helium, purity ≥ 99.995%, pressure 0.25 ± 0.1MPa Helium, purity ≥ 99.995%, pressure 0.25 ± 0.1MPa /
Auxiliary gas Oxygen, purity ≥ 99.5% when measuring hydrocarbon element, purity ≥ 99.995% when measuring nitrogen element, pressure 0.25 ± 0.1MPa Oxygen, purity ≥ 99.5% when measuring hydrocarbon element, purity ≥ 99.995% when measuring nitrogen element, pressure 0.25 ± 0.1MPa Oxygen, purity ≥ 99.5% when measuring hydrocarbon element, purity ≥ 99.995% when measuring nitrogen element, pressure 0.25 ± 0.1MPa Oxygen purity≥99.5%
Power gas Inert gas, no oil, no water, pressure 0.29±0.1MPa Inert gas, no oil, no water, pressure 0.29±0.1MPa Inert gas, no oil, no water, pressure 0.29±0.1MPa /
Power ≤4.5kw ≤4.5kw ≤4.5kw ≤4.5kw
Power supply 220VAC±10%, 50HZ 220VAC±10%, 50HZ 220VAC±10%, 50HZ 220VAC±10%, 50HZ
Type Horizontal (can be placed on table) Horizontal (can be placed on table) Horizontal (can be placed on table) Horizontal
Overall dimensions(mm) 690×740×720 690×740×720 690×740×720 920×470×440
Net wight(kg) 105 102 102 47

 

Carbon Hydrogen and Nitrogen analyzer for coal and coke

                    Automatic moisture /Ash content tester 

Contact Details
Serve Real Instruments Co.,Ltd

Contact Person: Mr. Patrick

Tel: 00-86-18014755745

Fax: 86-86-18621861107

Send your inquiry directly to us (0 / 3000)

Other Products
Request A Quote

E-Mail | Sitemap

Privacy Policy | China soil triaxial tester Supplier. Copyright © 2016 - 2022 civil-instruments.com. All Rights Reserved. Developed by ECER